Рус / Eng

HELICOID TURBINE FLOW CONVERTERS ТПРГ10¸ ТПРГ150

 
 
Number in Public Register    23153-08
Recalibration interval   2 years max
Average lifetime          10 years
 
Mean time before failure 40 000 h min
 
 
DEGREE OF PROTECTION
IP54 according to ГОСТ14254
 
EXPLOSION PROTECTION CLASS
1ExibIIBT3
 
 
PURPOSE
 
Helicoid turbine flow converters ТПРГ are designed to convert the liquid volume flow rate into a frequency electric signal of a sinusoidal form. They are used in processing stations, bench equipment, charging stations of petroleum-refining factories as well as in the diesel oil metering systems.
 
PRINCIPLE OF OPERATION
 
The ТПРГ principle of operation is based on the liquid volume flow rate conversion into the angular velocity of the turbine rotation (on the supports in the form of the friction bearings) placed in the stream.
 
MEASURED MEDIUM
 
Petroleum and products of its refining, hydraulic system fluids, industrial oils, diesel fuel, hydrocarbon fuels, water.
 
 
HELICOID TURBINE FLOW CONVERTERS ТПРГ10 ¸ ТПРГ150 BASIC TECHNICAL CHARACTERISTICS
 
Parameter
Value
Measured medium viscosity, mm2/s (sSt)
from 0.55 to 50
Basic tolerated relative conversion error limit for a particular viscosity range, %
±0.5
          within the range Qmin – Qmax (ver.1)
±0.5
          0.35 Qmax - Qmax (ver.2)
±0.25
          for one value 0.35 Qmax - Qmax (ver.3)
±0.15
Measured medium temperature range, ºC
from -40 to +125
Ambient temperature, ºC
from -40 to + 80
 
 
 
Тип ТПРГ
Ду
(Qmin – Qmax), l/s (m3/h)
Qnom, l/s (m3/h)
Pmax, MPa (kgf/cm3)
ТПРГ10-8-2
10
0.03 - 0.25 (0.108 – 0.9)
0.125 (0.45)
6.3 (63)
ТПРГ 10-9-2
1.6 (16)
ТПРГ 12-8-2
12
0.05 – 0.45 (0.18 – 1.62)
0.225 (0.81)
6.3 (63)
ТПРГ 12-9-2
1.6 (16)
ТПРГ 20-8-2
20
0.16 – 2.5 (0.576 – 9.0)
1.25 (4.5)
6.3 (63)
ТПРГ 20-9-2
1.6 (16)
ТПРГ 32-8-2
32
0.4 – 6.0 (1.44 – 21.6)
3 (10.8)
6.3 (63)
ТПРГ 32-9-2
1.6 (16)
ТПРГ 40-10-2
40
0.6 – 10 (2.16 – 36.0)
5 (18.0)
6.3 (63)
ТПРГ 40-11-2
1.6 (16)
ТПРГ 50-10-2
50
0.8 – 16 (2.88 – 57.6)
8 (2.88)
6.3 (63)
ТПРГ 80-10-2
80
2 – 40 (7.2 – 144.0)
20 (72.0)
6.3 (63)
ТПРГ 100-10-2
100
3 – 60 (10.8 – 216.0)
30 (108.0)
6.3 (63)
ТПРГ 150-10-2
150
7 – 140 (25.2 – 504.0)
70 (252.0)
6.3 (63)
Note:
(Qmin – Qmax) – measured flow rate range
Qnom – rated flow rate
Pmax – measured liquid maximum operating pressure
Ду - flow section internal diameter
 
 
DESIGNATION FOR REQUISITIONING
 
When ordering it is necessary to specify the converter internal diameter (Ду), type, the measured medium viscosity and pressure.
 
Example
 
 “Helicoid turbine flow converter ТПРГ20-8-2 ЛГФИ.407221.027ТУ” – a converter with Ду = 20mm with a nipple edge joint for pressure 6.3 МPа connection on friction bearings.
 
 
ТПРГ 10 ¸ ТПРГ 32
OVERALL AND MOUNTING DIMENSIONS
 
ТПРГ type
Dimensions, mm
Ду
d
D
L
C
B
ТПРГ 10-8-2, ТПРГ 10-9-2
10
14,5H11
M20x1.5-6e
80h12
81.5±1
34
ТПРГ 12-8-2, ТПРГ 12-9-2
12
16,5H11
M24x1.5-6e
80h12
85.5±1
38.5
ТПРГ 20-8-2, ТПРГ 20-9-2
20
24,5H11
M33x1.5-6e
100h12
94±1
45
ТПРГ 32-8-2, ТПРГ 32-9-2
32
37,2H11
M48x2-6e
125h12
110±1
60.5
 
 
ТПРГ 40 ¸ ТПРГ 150
OVERALL AND MOUNTING DIMENSIONS
 
ТПРГ type
Dimensions, mm
Ду
d1
d2
D
L
C
ТПРГ 40-10-2
40
48H11
55H11
61
140h12
112.5±1
ТПРГ 50-10-2
50
60H11
67H11
73.5
160h12
125.5±1
ТПРГ 80-10-2
80
90H11
98H11
106
200h12
157±1
ТПРГ 100-10-2
100
110H11
118H11
123
225h12
175±1
ТПРГ 150-10-2
150
164H11
172H11
180
300h12
228.5±1
 
1. By the Customer's request ТПРГ can be delivered for operation in the following measured medium viscosity ranges, mm2/s:
range I……………….from 0.55 to 10
range II………………from 10 to 20
range III……………..from 20 to 50
 
2. The installation kit is delivered by the Customer's request.