Рус / Eng
PURPOSE
 
System for measuring of oil-water-gas mixture parameters "ULTRAFLOW" (hereinafter – the system) is designed for continuous and simultaneous flow measurement of liquid and gas components of a multi-component flow with different structure and flow mode, without preliminary separation, as well as for measurement of water volume concentration (watering) in the liquid component of the oil-water-gas mixture.
RANGE OF APPLICATION
 
System for measuring of oil-water-gas mixture parameters "ULTRAFLOW" can be used in multi-phase practice of well products collecting. The system is characterized by small mass and dimensions and can be easily mounted on the objects of oil production and oil-water-gas mixture transportation. A monoblock variant of the "Ultraflow" embodiment is the most perspective when used in the multi-phase practice of well products collecting. The system interface and software provide its integration into the upper level automatic control system. "Ultraflow" meets the requirements of ГОСТ P 8.615-2005 ГСОЕИ "Measurements of Quantity of Oil and Oil Gas Extracted from the Subsoil. General Metrological and Technical Requirements" and is recommended for use in the oil fields to measure quantity of crude oil and oil gas.
Name
Value
Pressure measurement range, MPa*
from 0 to 4.0
Temperature measurement range, ºC
from -10 to +60
Liquid volume flow measurement range, m3/day
from 10 to 400
Gas volume flow measurement range, m3/day**
from 15 to 1000
Watering measurement range, %
from 0 to 100
Tolerated absolute measurement error limits:
 
of temperature, ºC
±1.5
of watering, %
at watering up to 70%
at watering over 70%
 
±2.5
±3.5
Tolerated relative measurement error limits, %:
 
of liquid volume flow rate
±2.5
of gas volume flow rate
±5
of current time
±0.01
of pressure, % of the upper measurement limit, max
±1.5
Pressure drop in water channel, max, kPa (kgf/cm2)***
40 (0.4)
Power supply – AC voltage
V (220V) frequency (50±1)Hz
Power consumption, VA
250 max
Water channel mounting length, mm
1500 max
Mass, kg, max (measuring water channel, distributor РМ-БП)
65, 16
Average lifetime, years
10
* Pressure upper measurement limit is determined by the pressure transducer when ordering but not more than 4 Mpa
** Under the operating measurement conditions
***At the maximum viscosity of 300 mm2/s (300 sSt) and liquid flow rate of 400 m3/day
 
CONTROLLED MEDIUM PARAMETERS
Name
Value
Viscosity, mm2/s (sSt)
300 max
Mineralization, g/dm3 (g/l)
200 max
Contamination, %
2 max