Рус / Eng

Ultrasonic Level Alarm УСУ-1

The controlled liquid: petroleum and its light fractions, water and any other liquids forming no deposits on the sensing element material and making no damage to it.
 
The alarm can be used as a detector of liquid presence in the controlled volume. It can be mounted on an object vertically or horizontally with spatial orientation.
 
The alarm has "an explosion-proof" level of explosion protection according to state standard ГОСТ P51330.1 provided by "d" types of explosion protection according to ГОСТ P51330.1 and "spark-proof electric circuit" according to ГОСТ P51330.10, explosion protection marking "1Exibll CTX" and is designed for mounting outdoors and indoors in places where mixtures of air with burning gases, vapours and dust can be formed which are capable of exploding in the presence of a source of firing.
 
The alarm relating to the explosion-proof electric devices for outdoor mounting (group II) of temperature class T5 (ГОСТ P51330.0) is designed for operation in macroclimatic regions УХЛ according to ГОСТ 15150: location category 1 – for the УХЛ version.
 
PURPOSE
Liquid level control in open and closed tanks under pressure in technological plants at enterprises of chemical, petrochemical, medical, food and other industries, as a detector of liquid presence (or absence) in the controlled volume. It is possible to use in barrels of the "Tandem" type end gaskets.
 
The alarm meets the requirements of "General Rules for explosive chemical, petrochemical and petroleum refining productions" ПБ09-170-97, can be used in explosive areas where formation of mixtures of air with gases and vapours related to category IC and temperature group T5 (ГОСТ 12.2.020-76) is possible.
 
 
 
RANGE OF APPLICATION
According to the explosion protection marking ch. 7 of ПУЭ, ЛГФИ.477733.001ПС and other normative documents regulating use of explosion-proof electric equipment mounted in explosive areas of chemical, petroleum, petrochemical industries, main pipeline transportation and other productions and objects connected with handling or storage of explosive and toxic substances and mixtures as well as handling equipment.
 
PRINCIPLE OF OPERATION
The alarm principle of operation is based on change of the ultrasonic echo-signal parameters of the alarm sensing element when it is immersed into liquid.
When the liquid level is above the alarm sensing element, the alarm optical indicator glows yellow, the alarm contactor chain is opened.
When the liquid level is under the alarm sensing element, the alarm optical indicator glows yellow, the alarm contactor chain is closed.
DESIGNATION FOR REQUISITIONING
It is necessary to specify the distance between the supporting surface and the sensing element (A) – 60, 80, 100, 120, 160, 250, 270, 320, 350, 400, 430, 450, 500, 600, 800, 1200, 1500mm and the connection type (Ш) – nipple, (M) – captive nut. Variant with distance (A) made to order is available. Distance between the sensing element and the end surface (B) - 11±0.1.
 
MEAN TIME BETWEEN FAILURES
10 000h min
 
AVERAGE LIFETIME
12 years min
 
 
THE ALARM MATERIAL WHICH IS IN CONTACT WITH THE CONTROLLED MEDIUM
12X18H10T ГОСТ 19941-81
and 12X18H9T-B ТУ 14-1-3957-85
 
EXPLOSION PROTECTION CERTIFICATE
ЦС ВЭ ИГД № 2001.С263 dated 24.12.2001
 
HYGIENIC CERTIFICATE
№ 52.НЦ15.944.n.1863.12.00 dated 13.12.2000
 
 
EXAMPLE
The alarm with the distance between the supporting surface and the sensing element 80mm:
Ultrasonic level alarm УСУ-1, L=80 ЛГФИ. 407733.001ТУ
 
 
 
BASIC TECHNICAL CHARACTERISTICS

Parameter
Value
Controlled medium parameters
temperature, ºC
from -40 to +400
excessive pressure, MPa
up to 6
density, kg/m3
not rated
viscosity is not rated but it is necessary to take into consideration increase of actuation and release time for the time of liquid draining from the sensing element.
Actuation error, mm
in vertical mounting
±1
in horizontal mounting
±15
Actuation and release time, ms
from  150 to 210
Actuation and release time hysteresis, s
from 1.5 to 2.1
DC supply voltage, V
14 – 28 (nominal – 24)
Consumed current, max, mA
35
Voltage switching by the alarm output switch, V
from 18 to 28
Current switched by the alarm output switch, A, max
0.1
Output switch leakage current at the switch voltage 28V, mcA, max
10
Overall dimensions, mm, max
(11+A+260)x100x155
Mass, kg, max
2.5
Operating and mounting conditions
Ambient temperature range, ºC
from -40 to +85
Location category (ГОСТ 15150-69)
1
Version (ГОСТ 15150-69)
УХЛ
Housing protection degree (ГОСТ 14254-96)
IP67
The alarm explosion protection marking
1Exibll CT 5X

 
OVERALL DIMENSIONS
 
The alarm provides:
- indication of the fed supply voltage presence;
- indication of moments when the preset level (high, low) is reached;
- the electric circuit switching when the controlled level (high, low) is reached for data communication with other devices.