UNIVERSAL COLD AND HOT WATER METERS WITH MAGNETIC PROTECTION CBK15-3-1,CBK15-3-2, СBK15-3-8, СBK15-3-8-1 СBK15-3-7, СBK15-3-7-1 CBK20-5, CBK20-5-1

Recalibration interval 4 years for hot water
6 years for cold water
Warranty period 40 months
Lifetime 12 years min
PURPOSE
According to state standard ГОСТ P50601 universal cold and hot water meters are designed for drinking cold and hot water metering by individual consumers. They are capable to transfer data by communication lines.
By ambient air temperature and humidity resistance the meter version corresponds to category B4 of state standard ГОСТ 12997.
In the metrological classification the meters correspond to class B when mounted horizontally, and class A when mounted vertically according to state standard ГОСТ Р50193.1.
Depending on the internal diameter the meters are available in several dimension types (ref. the table).
For remote transfer of the measurement results water meters with pulse output (magnetically operated sealed switch) providing 1 liter discreteness are recommended. The water meters have highly effective protection from magnetic fields of permanent magnets.
Certificate of conformance POCC RU.АЯ74.B311348
Sanitary certificate №52.НЦ.14.000.T001164.08.08
Precision characteristics:
The limit of the liquid volume measurement tolerated relative error:
±5 % within the range from qnin to qt
±2 % within the range from qt to qmax (inclusive)
Basic Technical Characteristics
|
Device designation |
CBK 15-3-1,CBK 15-3-2,
СBK15-3-8, СBK15-3-8-1
СBK15-3-7, СBK15-3-7-1 |
СВК 20-5
CBK 20-5-1 | |||
|
Parameter |
Value | ||||
|
Metrological class |
Class А |
Class В |
Class А |
Class В | |
|
Temperature of medium measured, °С |
from +5 to +90 | ||||
|
Ambient air temperature at relative humidity of 80%, ºC |
from +5 to +50 | ||||
|
Water operating pressure, MPa, max |
1 | ||||
|
Internal diameter, mm |
15 |
20 | |||
|
Water flow rate, m3/h
minimum (Qmin):
transitional (Qt):
rated (Qn)
maximum (Qmax) |
0.06
0.15
1.5
3 |
0.03
0.12
1.5
3 |
0.1
0.25
2.5
5 |
0.05
0.2
2.5
5 | |
|
Water maximum volume, m3 | |||||
|
for 24 hours |
37.5 |
62.5 | |||
|
for a month |
1125 |
1875 | |||
|
Pressure loss, МPа (bar), max |
0.1 (1) | ||||
|
Sensitivity threshold, max |
0.5 Qmin | ||||
|
Counter mechanism capacity, m3 |
99999 | ||||
|
Nominal diameter of the pipe threaded connection, inch |
G3/4B |
G1B | |||
|
Mass, kg, max |
0.75 |
1.5 | |||
|
Overall dimensions, mm |
110х72х93 (max) СВК 15-3-1
110x72x78.5 (max) CBK 15-3-2
110x71x79 (max) CBK 15-3-8
110x71x98 (max) CBK 15-3-8-1
80x71x79 (max) СBK 15-3-7
80x71x98 (max) CBK 15-3-7-1 |
110x72x78.5 (max)
110x72x93 (max) | |||
DESIGNATION FOR REQUISITIONING
When ordering it is necessary to specify internal diameter of the inlet and outlet pipe connections, maximum measured flow rate and version (pulse output)
Example
Water meter СВК 15-3-1 ТУ 4213-021-07513518-03
15 –internal diameter of the inlet and outlet pipe connections (mm);
3 (5) - maximum measured flow rate (m3/h);
1 – version (pulse output)